Download Print this page

KVH Industries TracVision M7 Replacement Instructions page 3

Rf pcb
Hide thumbs Also See for TracVision M7:

Advertisement

d. Label the two RF cables as shown in
using a 7/16" open-end wrench, disconnect the two RF
cables from the RF PCB.
Figure 2 RF PCB Connections/Screws
Connectors
e. Disconnect the two Molex wires from the main PCB.
f. Using a #1 Phillips screwdriver, remove the four screws
securing the RF PCB (see
g. Remove the faulty RF PCB.
h. Reverse this process to install the replacement RF PCB.
Then reinstall the radome and reconnect power to the
TracVision system.
Step 2 - Check the Main PCB Software Version
You might need to update the software in the TracVision system's
main PCB, depending on its software version. The following
instructions explain how to check the currently installed main PCB
software version.
a. Follow the instructions provided in the TracVision M7
User's Guide to connect a PC to the TracVision system.
b. Double-click the KVH Flash Update Wizard shortcut on
your PC's desktop to start the Flash Update Wizard.
c. Type HALT then press Enter.
= Screws (x4)
Molex
To IRD
RF PCB Replacement Instructions
Figure
2. Then,
RF
Connectors
To LNB
Figure
2).
TracVision M7
3