Download Print this page

KVH Industries TracVision M7 Replacement Instructions page 2

Rf pcb
Hide thumbs Also See for TracVision M7:

Advertisement

TracVision M7
RF PCB Replacement Instructions
Step 1 - Replace the RF PCB
2
a. Using a #2 Phillips screwdriver, remove the six #10-32
screws securing the radome. Then remove the radome
and set it aside in a safe place.
Figure 1 Radome Removal/PCB Cover Screws
2
1
PCB Cover
6
5
b. Using a #1 Phillips screwdriver, remove the four screws
securing the PCB cover at locations 1-4 (see
Using a 3/8" nut driver or wrench, remove the three
nuts and washers at locations 5-7.
c. Carefully position the cover to allow access to the PCB.
NOTE: Be sure to handle the cover carefully to avoid damaging or
dislodging PCB components.
NOTE: The PCB module is static-sensitive. Ensure that you take the
necessary grounding precautions before handling.
Radome
4
3
Inverter PCB
(not present on all systems)
Baseplate
7
Figure
1).

Advertisement