Advertisement

Quick Links

http://www.adsequip.com/
User's Manual of
Beyond 300/301 Delivery System
P/N:8023488 Version:A Date:2017-08-01

Advertisement

Table of Contents
loading

Summary of Contents for ADS Beyond 300

  • Page 1 User's Manual of Beyond 300/301 Delivery System P/N:8023488 Version:A Date:2017-08-01...
  • Page 2 Copyrights ADS makes no warranty of any kind with regard to this material , i n c l u d i n g b u t n o t l i m i t e d t o , t h e i m p l i e d w a r r a n t i e s o f merchantability and fitness for a particular purpose.
  • Page 3: Table Of Contents

    User's Manual of Beyond 300/301 Delivery System CONTENTS Introduction………………………………………………………… 1 1.1 Products information……………………………………………1 1.2 Symbols explanation……………………………………………1 Specifications………………………………………………………… 3 Application notice…………………………………………………… 3 3 . 1 A t t e n t i o n s … … … … … … … … … … … … … … … … … … 3 Warning information……………………………………………...
  • Page 4: Introduction

    User's Manual of Beyond 300/301 Delivery System 1 Introduction 1.1 Products information Unit conversion • Name:Delivery system • Model:Beyond 300/301 • Working conditions: 0.2MPa 29psi ①Ambient temperature:5 ℃~40 ℃; 0.4MPa 58psi ② Relative humidity:≤ 80%; ③ Nominal Voltage :AC110 V±22 V;...
  • Page 5 User's Manual of Beyond 300/301 Delivery System Symbols Explanations Refer to instructions Notice Refer to attatched document Backrest Down Avoid Electric Shock Backrest Up  Ground protection Chair Down Setup Button Chair Up Spitting position Program Chair Position 1 Program Chair Position 2...
  • Page 6: Specifications

    User's Manual of Beyond 300/301 Delivery System 2 Specifications Table 2 Light illuminance 8000-40000 Lux Max load of delivery head 2.5kg Ambient temperature 5 ℃~40 ℃ Air supply pressure 72.5psi~101.5psi Water supply pressure 29~58psi 3 Application notice 3.1 Attentions Before operating the unit, please read the manual carefully •...
  • Page 7 User's Manual of Beyond 300/301 Delivery System • The equipment should not be used for purposes other than intended use . • The water source of the system should be purified tap water, the water used shall conform to the local water standards, water hardness ≤ 450 mg/L .
  • Page 8: Warning Information

    User's Manual of Beyond 300/301 Delivery System 3.2 Warning Information • You should read and understand the contents of the instructions carefully before operating the equipment. • Operation should follow all warnings and cautions on the instrument . • The power socket cable should be in accordance with the standard configuration and the ground wire must be secure .
  • Page 9: Sizes

    User's Manual of Beyond 300/301 Delivery System 4 Sizes(unit:inches) Beyond 300 P/N:8023488...
  • Page 10 User's Manual of Beyond 300/301 Delivery System Beyond 301 P/N:8023488...
  • Page 11: Operations

    User's Manual of Beyond 300/301 Delivery System 5 Operations 5.1 Water supply system A 1.5L quick-disconnect water bottle mounted on the front rotary arm ,provide simple and convenient solution to control water quality. 1. Air Q/D: This air output provides 80 psi Figure 1 output to run accessories for the user.
  • Page 12: Assistant's Control

    User's Manual of Beyond 300/301 Delivery System Assistant's control The assistant's control can rotate as the figure shown. Figure 2 P/N:8023488...
  • Page 13: Cuspidor (Optional)

    User's Manual of Beyond 300/301 Delivery System 5.3 Cuspidor (optional) Figure 3 The cuspidorl can rotate as the figure shown. Note: Beyond 300 system is non-cuspidor type. • To realize cup filling function and bowl rinsing function, just press the two buttons beside the cup filling nozzle.
  • Page 14: Dentist Unit

    User's Manual of Beyond 300/301 Delivery System Figure 5 Adjust the needle valves • If you want to change the duration of cup filling or bowl rinsing, you need to remove the two nozzles and take off the upper shell of the...
  • Page 15: Level Arm Adjustments

    User's Manual of Beyond 300/301 Delivery System 5.4.1 Level arm adjustment 1. Remove the plugs, change the Figure 7 tightness of the three screws to adjust the damping force of level arm . Note: 1、3 of damping adjustment, 2 of stop adjustment.Loosen the screws in counterclockwise, tighten in clockwise.
  • Page 16: Control Panel

    User's Manual of Beyond 300/301 Delivery System 5.5 Control panel Figure 9 Main control panel Assistant's control panel 5.5.1 System state The light-on of control panel indicates a normal working state, and you can operate normally P/N:8023488...
  • Page 17: Chair Position Buttons

    User's Manual of Beyond 300/301 Delivery System 5.5.2 Chair position buttons Symbols Functions Symbols Functions Backrest Up   Backrest Down Spitting position   Chair Down  Program Chair Positions 1   Chair up  Program Chair Positions 1 Original position Program Chair Positions 1 5.5.3 Initial settings of the chair...
  • Page 18: Initial Settings Description

    User's Manual of Beyond 300/301 Delivery System Hydraulic system initial settings : 1. Press “P” button about 12 second until the buzzer sound 2 short beeps (the indicator flashes twice and then illuminates),enter initial setup state; press P1,the buzzer sound 1short beep( P light off),escape setup state.
  • Page 19: Chair Positions Description

    User's Manual of Beyond 300/301 Delivery System 5.5.5 Chair positions description . Backrest Up Press this button continuously and the backrest will move upwards. When the backrest reach the desired position, stop pressing the button and the backrest will stop immediately.
  • Page 20: Foot Control

    User's Manual of Beyond 300/301 Delivery System . Original position Press the button, the chair and backrest will move to the original position automatically(Original position : backrest highest , the chair lowest) and light off . Press this button again , the chair returns to former position and light on.
  • Page 21: Junction Box

    User's Manual of Beyond 300/301 Delivery System 5.7 Junction box Located in the junction box, the Utility Center comes factory preset at 40psi for Water pressure and 80 psi for Air pressure. All regulator adjustments should be made with the Master On/Off toggle in the On position.
  • Page 22: Functions Introduction

    User's Manual of Beyond 300/301 Delivery System 6 Functions introduction 6.1 Valves layout of delivery head Figure 11 DE-5 delivery head Water Coolant Master On/Off Air Coolant Syringe air control Drive Air Pressure Gauge Syringe water control Handpiece Flow Controls...
  • Page 23 User's Manual of Beyond 300/301 Delivery System Air Brake: The air brake toggles activate and release the pneumatic brake in the level arm. Air Coolant : This master control valve adjusts the amount of air coolant flow to all of the handpieces. Rotate in counterclockwise to increase flow, clockwise to decrease flow.
  • Page 24 User's Manual of Beyond 300/301 Delivery System Figure 12 Foot control Turn off mist spray Turn on mist spray Hint:Adjust the drive air pressure to meet the demands of handpiece manufacturer's drive air pressure specifications. Refer to your handpiece documentation for the drive air pressure specification.
  • Page 25: 3-Way Syringe Adjustment

    User's Manual of Beyond 300/301 Delivery System 6.3 3-way syringe adjustment Figure 13 3-way syringe adjustment P/N:8023488...
  • Page 26: Maintenance And Sterilization Instructions

    Transfer surface refers to the surface area that contaminated from contacting with the instruments or other inactive object. ADS company recommends isolating protection for all applicable touch surfaces and transfer surfaces. The partition used must be a plastic film approved the Food & Drug Administration. The plastic films should be taken off and discarded after the treatment of each patient.
  • Page 27: Clean Dirty Collector

    User's Manual of Beyond 300/301 Delivery System 7.3 Clean dirty collector Keep weekly maintenance, increase Figure 15 maintenance times when use frequently . To clean the collector: 1.Unscrew the dirty collector counterclockwise and remove it; 2.Discard used cotton. 3.Put some cotton into dirty collector;...
  • Page 28 We reserve the right to make any alterations which may be due to technical improvements. Ajax Dental System Inc. Add: 13900 Sycamore Way, Chino, CA 91710 Tel: (626) 620 0456 E-mail: ads@adsequip.com http://www.adsequip.com/...

This manual is also suitable for:

Beyond 301

Table of Contents