Fileconfig-Act; Fileconfig-Stby; Frcdsw - Fujitsu FLM 150 ADM Maintenance And Trouble Clearing

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
3.33
FILECONFIG–ACT
Table 3-31: FILECONFIG–ACT (File Configuration-Active)—Alarm Event
AID
Direction
Type
COM
NA
3.34
FILECONFIG–STBY
Table 3-32: FILECONFIG–STBY (File Configuration-Standby)—Transient Condition
AID
Direction
Type
COM
NA
3.35

FRCDSW

Table 3-33: FRCDSW (Forced Switch)—Standing Condition
AID Type
Direction
OC3
OC12
OVTG
VT1
STS1
COM
(If SYNCMSG =Y)
Issue 9, May 1999
Probable Cause
A mismatch failure of the file
configuration among active
nonvolatile memories (NVMs).
Probable Cause
A mismatch failure of the file
configuration among standby
NVMs.
Probable Cause
NA
A manual (forced) switch to either
Working or Protect is in effect. No
automatic switching can occur
until the forced switch is released.
NA
A manual (forced) switch of the
clock source.
FNC and FNC Customer Use Only
3.33: FILECONFIG–ACT
Suggested Corrective Action
• Make sure the program files are correct.
This condition could occur when the NE is
powered up if the existing program files
are incorrect.
Suggested Corrective Action
Verify that all program files for the new
generic issue are installed in the Standby
NVM and that the correct configuration file is
present in the Standby NVM. After updating
the files, the INIT-SYS will be allowed.
Note: With this condition, the NE will not
allow the new generic issue to be started. The
system will remain at the previous software
version until another INIT-SYS is completed,
after corrective action.
Suggested Corrective Action
• Check to see if there is a valid
reason to maintain the forced
switch condition.
• If appropriate, release the forced
switch.
• Check to see if there is a valid
reason to maintain the forced
switch condition.
• If appropriate, release the forced
switch.
Vol. ll, Page 480.3-21