Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 190

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 3
Retrieve the Group Configuration to show how the slot is provisioned.
a. From the Provisioning menu, choose System, then choose Set Group
Configuration. A dialog box opens.
b. Select Group Configuration.
c. Click Retrieve to show the current settings. The following configurations
are possible:
- Groups 1 and 2—OC3, EC1, or OC12
- Group 3—D1, D3, EC1, or D1E
- Groups 4 and 5—D1, D3, EC1, D1E, OC3, F6-4WP, F6-7W, LAN, or
Is the group provisioned correctly?
Click Close.
Call the Technical Assistance Center at 1-800-USE-FTAC
(1-800-873-3822) for assistance.
WARNING:
The following action has the potential for dropping traffic if not done correctly!
Delete any cross-connects that exist to/from the group.
Step 4
a. From the Provisioning menu, choose Add/Drop.
b. Select Disconnect and the type of circuit to disconnect (1-Way, 2-Way, or
Broadcast).
c. Click on each end of the circuit to be disconnected and repeat for each
cross-connected circuit.
d. Click Send and check the resulting Confirmation box to verify that only
connections to the appropriate Group are slated for disconnection. If
accurate, click OK to make the disconnections.
e. Click on Close.
Issue 9, May 1999
D3U
If Yes:
FNC and FNC Customer Use Only
5.8: Correcting a Mismounted Unit
If No:
Go to Step 4.
Click Close.
Vol. ll, Page 480.5-28