B1Err; B2Err - Fujitsu FLM 150 ADM Maintenance And Trouble Clearing

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
3.8

B1ERR

Table 3-6: B1ERR (Error Data Generated)—Standing Condition
AID
Direction
Type
OC-3
TRMT/RCV
OC-12
TRMT
150 ADM
OC-3/
OC-12
ADDED
SIGNAL
3.9

B2ERR

Table 3-7: B2ERR (B2 Error Data Generated)—Standing Condition
AID
Direction
Type
EC1/HC
TRMT/RCV
OC3
TRMT/RCV
OC12
TRMT
150 ADM
OC-3/
OC-12
ADDED
SIGNAL
Issue 9, May 1999
Probable Cause
CONN-TSTSIG-OC3 has been
executed.
CONN-TSTSIG-OC12 has been
executed.
Probable Cause
CONN-TSTSIG-EC1 has
been executed.
CONN-TSTSIG-OC3 has
been executed.
CONN-TSTSIG-OC12
has been executed.
FNC and FNC Customer Use Only
Suggested Corrective Action
• Verify that the facility testing is
complete.
• Execute the DISC-TSTSIG-OC3
command.
• Verify that the facility testing is
complete.
• Execute the DISC-TSTSIG-OC12
command.
Suggested Corrective Action
Verify that the facility testing is complete.
Execute the DISC-TSTSIG-EC1 command.
Verify that the facility testing is complete.
Execute the DISC-TSTSIG-OC3 command.
Verify that the facility testing is complete.
Execute the DISC-TSTSIG-OC12 command.
3.8: B1ERR
Vol. ll, Page 480.3-9