Connecting

5.2 Connecting the device to power

5.2
Connecting the device to power
Before you connect the device please note
Note
The long-range power supply module is designed for operation on 120/230/240 V AC
networks. It is not necessary to adjust the voltage range.
Warning
Do not connect or disconnect power and data cables during thunderstorms.
Warning
The device is designed for operation on grounded power supply networks (TN systems to
VDE 0100, part 300, or IEC 60364-3).
Operation on ungrounded or impedance-grounded power networks (IT networks) is
prohibited.
Warning
The permitted rated voltage of the device must conform with local mains voltage.
Caution
The mains connector must be disconnected to fully isolate the device from mains. Ensure
easy access to this area.
A master mains disconnect switch must be installed if the device is mounted in a switch
cabinet. Always ensure free and easy access to the power inlet on the device, or that the
safety power outlet of the building installation is freely accessible and located close to the
device.
5-2
SIMATIC Rack PC 840 V2
Getting Started, Edition 04/2004, A5E00248069-02