Navien Mate EQM 580 User Manual page 23

Table of Contents

Advertisement

Setting the Automatic Temperature Control
Automatic temperature adjustment is an app-specific function that can be set only through
the app. Touch the automatic temperature adjustment tab to go to the setup screen. It can be
set by selecting from basic mode / custom mode. In the automatic temperature adjustment
mode, the temperature cannot be set with the touch button.
1) Default mode
You can set it by selecting the default mode.
The temperature can be set within the appropriate temperature range.
Slim mat type models (EQM5 ** - * S) : 86 ~ 91°F(30 ~ 33°C)
Set the left / right sleep time (5 ~ 10 hours).
Example of Default mode temperature change pattern
E.g.) When the start temperature is set to 39°F(34°C) for 8 hours
Starting
Section 1 starting
Temperature
temperature
93°F(34°C)
+ 2 degree
E.g.) Apprrox.1 hr /
95°F(35°C)
The temperature of the Navien Mate can be set within the appropriate sleeping temperature range. If set to
the highest temperature in the appropriate sleeping temperature range, the first zone (for the first hour) is
automatically maintained at the maximum temperature without increasing the temperature.
Use below 95°F(35°C) when sleeping or long-term use.
2) Personalized mode
Personalized mode can be selected to maintain the
desired temperature for the desired time.
Touch the Left Temperature Time / Right Temperature
Time tab to set the time and temperature.
Touch the + button to add a Personalized mode
section on the Sleep Time Setup screen.
When you touch the Sync button, the sleep time and
temperature will be set equal to the setting value on
the left.
Section 2 starting
temperature -5 degree
E.g.) Apprrox..3.5 hr / 88°F(31°C)
< Temperature change graph of Basic Mode >
Section 3 starting
temperature
-2 degree
E.g.) Apprrox..3.5 hr /
91°F(33°C)
23

Advertisement

Table of Contents
loading

Table of Contents