RE 6/RE 60 Electrical Tool
Troubleshooting (Continued)
SYMPTOM
Oil leaks from tool.
Motor runs but tool will
not complete a cycle.
Dies stop during
operation.
Cutting head stops dur-
ing operation.
RE 6/RE 60 Diagnostic Codes
Figure 7 – LED Diagnostic Codes
www.tiendaisso9000.com / www.isso9000.com.mx
10
POSSIBLE REASONS
Seal or mechanical problems.
Oil level low.
Oil level low.
Cutting edges are dull or broken.
Material not within blade specification.
Color
Light
Description
Green
Machine ON.
18V: Recharge battery
Red
Out of temperature range 15°F (-10°C) to 122°F (+50°C).
Service indicator after 30,000 cycles.
Yellow
NOTE: Tool will lock after 32,000 cycles.
Tool is locked. Service after 32,000 cycles or after a
malfunction.
SOLUTION
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Independent Service
center.
Replace dull or broken blades with appropriate
replacements.
Change to blade specified for material to be cut.
Icon