Compact 100-B Diagnostic Codes

SERVICE
SERVICE
MAINTENANCE
REQUIRED
BLINKING
LIGHT
TEMPERATURE
JAW PIN OPEN
BLINKING
LIGHT
LOW BATTERY
ON/OFF
LED DISPLAY
GREEN
RED
YELLOW
Blink 1x
Blink 1x
Blink 1x
Solid
Solid
Blinking
Blink 5x
Blink 5x
Solid
Blinking
Solid
Solid
Solid
Solid
Blink
Blink
20 Sec
20 Sec.
YELLOW
SOLID LIGHT
RED
SOLID LIGHT
GREEN
MEANING
Power-up light check.
Operate mode.
Jaw pin open.
Temperature out of range.
Low Battery.
Maintenance due (>20,000 presses).
Maintenance required (>22,000 presses).
Tool locked due to malfunctions.
Tool overheated/excessive current draw due to
tool malfunction.
Ridge Tool Company
Compact 100-B Pressing Tool
ACTION
Tool is ready to press.
Check jaw mounting pin to assure fully inserted.
Bring tool battery to range >32°F or <122°F
Replace or recharge battery. NOTE! Repeat Press.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.
Remove and replace battery. If still locked, contact Ridge
Tool Company, Technical Service Department at (800)
519-3456 for nearest Authorized Service outlet.
Allow tool to cool for 20 seconds. If condition occurs
repeatedly, contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.