Wiring Diagram: Outdoor Unit - Daikin Sky Air Advance Series Installation Manual

Hide thumbs Also See for Sky Air Advance Series:
Table of Contents

Advertisement

7 Technical data
7.3

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.
(1) Connection diagram
English
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper EEV
Lower EEV
Fan
ON
OFF
(2) Layout
English
Layout
Front
Left
Back
Position of compressor terminal
(3) Notes
English
Notes
X1M
NOTES:
1
Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1+DS2 switches.
2
When operating, do not short-circuit protective devices S1PH
and S1PL.
3
Refer to the combination table and the option manual for how
to connect the wiring to X6A, X15A and X77A.
4
Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green
(4) Legend
English
Legend
Optional
Part n°
Description
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
A3P
Printed circuit board (inverter)
Installation manual
18
Translation
Connection diagram
Only for ***
See note ***
Outdoor
Indoor
Upper electronic expansion valve
Lower electronic expansion valve
Fan
ON
OFF
Translation
Layout
Front
Left
Back
Position of compressor terminal
Translation
Notes
Connection
Indoor/outdoor communication
Earth wiring
Field supply
Protective earth
Field wire
Wiring depending on model
Option
Switch box
PCB
Translation
Legend
Optional
Part n°
Description
A4P
Printed circuit board (fan)
A5P
*
Printed circuit board (demand)
C503, C506 C507
Capacitor
(A3P)
DS1,DS2 (A1P)
DIP switch
E1H
*
Bottom plate heater
E1HC
Crankcase heater
F1U (A1P)
Fuse (T 3.15 A 250 V)
F8U, F9U
*
Fuse (F)
F101U (A4P)
Fuse
F101U, F102U (A2P)
Fuse
F601U (A3P)
Fuse
HAP (A1P, A3P,
LED (service monitor is green)
A4P)
K1R (A1P)
Magnetic relay (Y2S)
K3R (A3P)
Magnetic relay
K3R (A1P)
Magnetic relay (Y3S)
K5R (A1P)
Magnetic relay (E1HC)
K7R (A1P)
Magnetic relay (E1H)
L1R
Reactor
M1C
Compressor motor
M1F
Fan motor
PS (A1P,A3P)
Switching power supply
Q1DI
Earth leakage circuit breaker
Q1LD (A1P)
Earth current detector
R1T (A1P)
Thermistor (air)
R2T
Thermistor (discharge pipe)
R3T
Thermistor (suction pipe)
R4T
Thermistor (heat exchanger exit)
R5T
Thermistor (heat exchanger branch)
R6T
Thermistor (liquid pipe)
R7T
Thermistor (M1C body)
R24 (A4P)
Resistor (current sensor)
R300 (A3P)
Resistor (current sensor)
S1PH
High pressure switch
S1PL
Low pressure switch
SEG1~SEG3 (A1P)
7‑segment display
T1A
Current sensor
V1D (A3P)
Diode
V1R (A3P, A4P)
Diode module
X*A
Connector
X*M
Terminal block
Y1E
Electronic expansion valve (main)
Y2E
Electronic expansion valve (injection)
Y2S
Solenoid valve (4‑way valve)
Y3S
Solenoid valve (pressure equalization)
Z*C
Noise filter (ferrite core)
Z1F
Noise filter
RZA200+250D7Y1B
Sky Air Advance-series
4P573384-1 – 2019.04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rza200d7y1bRza250d7y1b

Table of Contents