Siemens Information and Communication Products
AT+CBST
Select Bearer Service Type
Test command
Response
AT+CBST=?
+CBST: (list of supported <speed>s), (list of supported <name>s), (list of supported <ce>s)
Parameter
see set command
Read command
Response
AT+CBST?
+CBST: <speed>,<name>,<ce>
OK
Parameter
see set command
Set command
Response
AT+CBST=
TA selects the bearer service <name> with data rate <speed>, and the connection element <ce>
[<speed>] [,<na-
to be used when data calls are originated. Values may also be used during mobile terminated data
me>
call setup, especially in case of single numbering scheme calls (refer +CSNS).
[,<ce>]]]
OK
Parameter
<speed>
<name>
<ce>
Reference
Note
GSM 07.07
GSM 02.02[1]: list of allowed combinations of the subparameters.
The PLMN influences the second air interface (to the terminator), therefore another mode may be
established from the network.
Version 8 dated 15.03.00
1
300 bps(V.21)
2
1200 bps(V.22)
3
1200/75 bps(V.23)
4
2400 bps(V.22bis)
5
2400 bps(V.26ter)
6
4800 bps(V.32)
7
9600 bps(V.32)
65
300 bps (V.110)
66
1200 bps (V.110)
68
2400 bps(V.110)
70
4800 bps(V.110)
71
9600 bps(V.110)
0
asynchronous modem
0
transparent
1
non-transparent