Siemens Information and Communication Products
43
network subset personalization PUK required
44
service provider personalization PIN required
45
service provider personalization PUK required
46
corporate personalization PIN required
47
corporate personalization PUK required
100
unknown
Note: all other values below 256 are reserved.
Table 5-5
Summary of CMS ERRORS
5.9.3
Summary of CMS ERRORS related to GSM 07.05
Code of <err>
Meaning
0...127
GSM 04.11 Annex E-2 values, see CMS ERROR codes related to GSM 07.07
128...255
GSM 03.40 subclause 9.2.3.22 values
300
ME failure
301
SMS service of ME reserved
302
operation not allowed
303
operation not supported
304
invalid PDU mode parameter
305
invalid text mode parameter
310
SIM not inserted
311
SIM PIN required
312
PH-SIM PIN required
313
SIM failure
314
SIM busy
315
SIM wrong
316
SIM PUK required
317
SIM PIN2 required
318
SIM PUK2 required
320
memory failure
321
invalid memory index
322
memory full
330
SMSC address unknown
331
no network service
332
network timeout
340
no +CNMA acknowledgment expected
500
unknown error
...511
all other values in range 256...511 are reserved
512
SIM not ready
513
Unread records on SIM
514
CB unknown error
Version 8 dated 15.03.00