Download Print this page

Specifications; Parts List; Wiring Diagram - SECO-LARM E-931-S33PRQ Manual

3ft polarized reflective photoelectric beam

Advertisement

ENFORCER 33ft Polarized Reflective Photoelectric Beam Sensor

Specifications:

Model
Polarized reflective
Type
photoelectric beam sensor
Sensing range
Operating voltage
12~250 VAC/VDC
12VDC
Standby: 20mA; Active: 40mA
Current draw (max.)
24VAC
Standby: 10mA; Active: 20mA
Response time
Light source
IR LED/Wavelength 740nm
Solid Green
Good beam signal, properly aligned
LEDs
Alternating flash
Poor beam signal
Solid Red
No beam signal, triggered
Trigger output
SPDT Relay output (NO/NC/COM)
Switching capacity
0.5A@120VAC/1A@30VDC
Tamper switch
N.C., 500mA@30VDC
IP Rating
Operating temperature
-4°~131° F (-20°~55° C)
Overview:
(without cover)
Beam sensor
Vertical
Beam
adjustment screw
sensor LED
Tamper switch
Terminal
block
Captive screw
Cable breakout
Dimensions:
4
13
/
"
16
(122mm)
2
/
"
1
8
(54mm)
2
/
"
3
8
(60mm)

Wiring Diagram:

• Polarity does not matter for the power input.
• Connect the N.C. tamper terminal to the
tamper circuit of an alarm control panel.
2

Parts List:

E-931-S33PRQ
1x Sensor
1x Reflector
1x Mounting bracket
33ft (10m)
1x Sensor hood
4x Cover screws
2x Mounting screws
10ms (max.)
1x Reflector mounting screw
1x Rubber ring
1x Cable connector
1x Manual
1x Removable terminal block
IP66
Hood
Cover
Mounting plate
Cable breakout
Cover
screw
Wire cable
connector
3
/
"
16
(4mm)
3
7
/
"
1
15
/
"
32
16
(82mm)
(49mm)
2
7
/
"
16
(62mm)
12~250
Relay
VAC/VDC
(Non-Polarity)
N.C. N.O. COM
SECO-LARM U.S.A., Inc.
Mounting:
1. Unscrew the four cover screws and remove the cover.
2. Loosen the captive screw and remove the sensor
from the mounting plate.
3. Using the included mounting screws, mount the
mounting plate to the wall.
4. Use the cable breakout and cable connector at
the bottom or rear of the sensor to run the wires.
5. Hang the sensor back on the plate and use the captive screw to secure it in place.
6. Re-attach the cover, replace the four screws, and attach the hood to the top of the sensor.
Wiring for the Bottom Cable Breakout
1. Puncture the cable breakout located at the bottom of
the sensor using a screwdriver or other object.
2. Insert the short end side of the cable connector
into the cable breakout hole and use the nut to
secure it, tightening with a wrench as needed.
3. Run the wires through the end cap and cable connector.
4. Then screw the end cap into the external side of the cable
connector to prevent water from entering the unit.
Wiring for the Rear Cable Breakout
1. Puncture the cable breakout located at the rear of
the sensor using a screwdriver or other object.
2. Run wires through the included rubber ring.
3. Install the weatherproofing ring with the wires already
installed in the cable breakout hole.
4. Make sure the ring is secure and there is no room for
water to get into the unit.
Alignment:
1. Mount the sensor and reflector so that they face
each other.
2. Connect power to the sensor. The LED will light as
11
/
"
indicated in the chart below.
32
(9mm)
3. Unscrew the 4 cover screws and remove the cover.
4. To find the correct alignment, slowly turn the lens
assembly left and right to adjust the horizontal angle.
5. Loosen the vertical adjustment screw to adjust the
vertical angle.
Tamper
6. Place the hood on the sensor by sliding the hood's
N.C.
ridges into the slots on the sides of the sensor.
7. Re-attach the cover, replace the four screws, and
attach the hood to the top of the sensor.
SECO-LARM U.S.A., Inc.
ENFORCER 33ft Polarized Reflective Photoelectric Beam Sensor
alignment
Solid green
Alternating flash
Solid red
Nut
Sensor
Cable
Rubber
Connector
neck
End cap
Rubber
Cable
ring
breakout
Horizontal
adjustment
±90°
Lens
Vertical
adjustment
±5°
Good beam signal,
properly aligned
Poor beam signal
No beam signal,
triggered
3

Advertisement

loading