Check
A) Hose-to-manifold connection (1) .
m warninG: if there is a leak at connection (1), re-tighten
the fitting with a spanner and recheck for leaks with soap-
and-water solution. if a leak persists after re-tightening the
fitting, turn off the gas. do not operate the GriLL.
Contact the Customer service representative in your area
using the contact information on our web site.
Log onto www.weber.com
B) Regulator-to-cylinder connection (2) .
C) The hose-to-regulator connection (3) .
D) Valves-to-manifold connections (4) .
m warninG: if there is a leak at connections (2), (3) or (4),
turn off the gas. do not operate the GriLL. Contact
the Customer service representative in your area using the
contact information on our web site.
Log onto www.weber.com
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water .

refiLLinG the LpG CYLinder

We recommend that you refill the LPG cylinder before it is completely empty . To refill,
take LPG cylinder to a "Gas LPG" dealer .
Removal of the gas supply cylinder:
A) Close cylinder valve (turn clockwise) (1) .
B) Unscrew regulator by turning POL fitting nut clockwise, by hand only (2) .
C) Lift cylinder off .
m important note: place dust cap on cylinder valve outlet
whenever the cylinder is not in use. only install the type of
dust cap on the cylinder valve outlet that is provided with
the cylinder valve. other types of caps or plugs may result
in leakage of LpG.