Connecting DC Power to IW-6300H-DC-x–K9
Connecting DC Power to IW-6300H-DC-x–K9
Warning:
When you connect or disconnect the power and/or alarm connector with power applied, an electrical arc
can occur. This could cause an explosion in hazardous area installations. Be sure that all power is removed from the
switch and any other circuits. Be sure that power cannot be accidentally turned on or verify that the area is
nonhazardous before proceeding. Statement 1058
Warning:
To reduce risk of electric shock, connect the unit only to DC power source that complies with the Safety
Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards or ES1 requirements in IEC 62368
based safety standards. Statement 1033
Warning:
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:
10A. Statement 1005
To route and connect the DC power cable to the IW-6300H-DC-x–K9 access point:
1.
Loosen captive bolts with 1/2" or 13-mm socket and open the access point cover.
2.
Route the cable through the 1/2" NPT
port.
3.
Use a wire stripper tool to remove the insulation from each 14 AWG (1.5mm
to provide adequate crimp on to ring terminals.
4.
Remove terminal strip screw and square washer.
5.
Insert ground wire into the internal ground.
6.
Connect DC line to terminal strip location. Tighten terminal strip screws to secure ring terminal and wire.
7.
Secure DC input cord to wire tie anchor adjacent to terminal strip.
8.
Close the access point cover.
1—Terminal block
2—Internal ground
10
2
) wire. Remove only enough wire