Technical Data - Napoleon BIPRO 825-3 User Manual

Table of Contents

Advertisement

Available languages

Available languages

Technical Data

The following table lists input values for the appliance.
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Do not tamper with or modify regulator. use only regulators which supply the pressure listed in the table
above. The grill is equipped with an internal regulator. This internal regulator has an outlet pressure of
24.5 mbar for propane/butane and must not be modified or adjusted. For replacement, use only the
regulator specified by the manufacturer.
This unit includes an internal regulator which stabilizes the gas pressure and improves grill performance.
This regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can
be used by a qualified service person when servicing the grill to determine if the regulator is functioning
properly. The screw within the pressure tap must always be kept tight, except when performing a pressure
test on the regulator (qualified service personnel only).
N415-0543CE-GB-DE JuNE 04.19
N415-0543CE-GB-DE.indd 5
Burner
Orifice Size
Main (Flame)
Main (Infra Red)
Rear
1.25 mm
Smoker
Warming
Gas Category
I
3B/P(30)
Orifice Sizes(see
above)
Gases / Pressures
Butane and Propane
at 30mbar
Countries
BE, BG, CY, DK, EE, FI,
FR, GB, HR, Hu, IS, IT,
LT, Lu, MT, NL, NO,
RO, SE, SI, SK, TR
(Gross) Heat Input (Total)
I
#60
15.2 kw
#60
7.6 kw
5.5 kw
#67
2.5 kw
#67
2.5 kw
I
3+(28-30/37)
I
I
Butane 28-30mbar
Butane and Propane
Propane 37mbar
BE, CH, CY, CZ, ES,
FR, GB, GR, IE, IT,
LT, Lu, LV, PT, SK, SI
Gas Usage (Total)
I
1120 g/hr
560 g/hr
400 g/hr
182 g/hr
182 g/hr
I
I
3B/P(37)
3B/P(50)
I
I
Butane and Propane
at 37mbar
at 50mbar
PL
AT, CH, DE, SK
www.napoleon.com
5
EN
I
6/4/2019 2:10:59 PM

Advertisement

Table of Contents
loading

Table of Contents