Ip Address Settings - Siemens SCALANCE W780 Configuration Manual

Simatic net industrial wireless lan to ieee 802.11n web based management
Hide thumbs Also See for SCALANCE W780:
Table of Contents

Advertisement

Configuring with Web Based Management
5.3 "Wizard" menu
5.3.1.3

IP Address Settings

Introduction
One of the basic steps in configuration of a device is setting the IP address. The IP address
identifies a device in the network uniquely.
Description
The Basic Wizard page contains the following boxes
● "DHCP Client" check box
Specify how the IP address will be assigned. There are two methods of assigning IP
addresses.
– Enabled
– Disabled
● "IP Address" input box
Enter an IP address that is unique within your network.
● "Subnet Mask" input box
Enter the subnet mask of the device.
● "Default Gateway" input box
Enter the IP address of the default gateway so that the device can communicate with
devices in other subnets, for example diagnostics stations, e-mail server.
68
The device obtains a dynamic IP address from a DHCP Server.
You enter the IP settings in the "IP Address" and "Subnet Mask" input boxes.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08