Configuring with Web Based Management
5.9 "Security" menu
5.9.4

Inter AP blocking

5.9.4.1

Basic

Note
• This tab is available only in access point mode.
• This WBM page can only be configured with the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5 907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
When should Inter AP blocking be used?
The clients connected to an access point can normally communicate with all devices of the
layer 2 network.
With inter AP blocking, the communication of the clients connected to the access point can
be restricted. Only the devices whose IP addresses are configured in "Allowed Addresses"
on the access point are accessible to the clients. Communication with other nodes in the
network is therefore prevented.
Description
The page contains the following box:
● "Refresh interval [s]" input box
Enter the refresh interval for the ARP table.