Sullair Dr; Lubrication Guide - Sullair DR13 125H Operator's Manual And Parts List

Industrial air compressor, 100-200 hp
Table of Contents

Advertisement

3.1 SULLAIR DR-- 13 COMPRESSOR PACKAGE
DR ---13--- SERIES 60 Hz
TYPE
HP
DR13 100H
100
DR13 125H
125
DR13 125HH
125
DR13 150H
150
DR13 150HH
150
DR13 200H
200
DR13 200HH
200
DR ---13--- SERIES 50 Hz
TYPE
HP
DR13 75H
100
DR13 75HH
100
DR13 90H
125
DR13 90HH
125
DR13 110H
150
DR13 110HH
150
DR13 132H
200
DR13 132HH
200
COMPRESSOR:
Type:
Configuration:
Bearing Type:
Lubrication:
Sump Capacity:
Duty Temperature:
Control:
Discharge Pressure:
MOTOR:
Type:
Size:
Voltage:
Service:
Starter:

3.2 LUBRICATION GUIDE

Sullair DR---13 compressors are factory filled with
Sullair lubricant (no. 02250057---198).
Mixing of other fluids within the compressor
should be authorized by the factory. Otherwise,
this may void all warranties.
Lubricant should be checked/changed every 8,000
hours or once a year, whichever comes first. The
LENGTH
IN/CM
144/366
144/366
144/366
144/366
144/366
144/366
144/366
LENGTH
IN/CM
144/366
144/366
144/366
144/366
144/366
144/366
144/366
144/366
Positive Displacement, Oil---Free, Twin Rotary Screws
Two---stages, Driven by Single Increaser Gear Box
Anti---Friction
Pressurize System for Bearings, Gears and Cooling Jackets
10 gallons (37.9 liters)
115_F (46_C) Max.
Electro---hydro---pneumatic
Maximum (see Table 3.1); Minimum 70 psi (4.8 bar)
TEFC Enclosure, NEMA Frames 365TSC through 445TSC,
Premium Efficient
100 through 200 HP , 2---pole speed
230V, 460V, 575V, 380V @ 60 Hz; 400V, 380---415V @ 50 Hz
50_C Ambient
Solid State Reduced Voltage with Disconnect Switch
WARNING
!
DIMENSIONS
WIDTH
HEIGHT
IN/CM
IN/CM
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
WIDTH
HEIGHT
IN/CM
IN/CM
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
72/183
80/203
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
Maintenance of all other components is still recom-
mended as indicated in the Maintenance section of
this manual.
Section 3
SPECIFICATIONS
WEIGHT
LB/KG
9350/4250
9900/4500
9900/4500
10100/4690
10100/4690
10350/4700
10350/4700
WEIGHT
KG
9750/4430
9750/4430
9900/4500
9900/4500
10100/4690
10100/4690
10350/4700
10350/4700
MAXIMUM
OPERATING
PRESSURE
PSI
125
125
150
125
150
125
150
MAXIMUM
OPERATING
PRESSURE
BAR
8.5
10.3
8.5
10.3
8.5
10.3
8.5
10.3
7