Preinstallation Checklist - GBC ORCA-I Operation Manual

Hide thumbs Also See for ORCA-I:
Table of Contents

Advertisement

ORCA-I Operation Manual
6HFWLRQ   ,QVWDOODWLRQ
Before an ORCA-I Laminator can be installed there
are a few requirements that must be met. Make
certain that each of the requirements listed in the
following preinstallation checklist are met before
beginning installation.
Failure to follow the preinstallation checklist
can result in damage to the laminator.
3UHLQVWDOODWLRQ &KHFNOLVW
Are doorways and hallways wide enough for the
laminator to be moved to the installation site?
Is there ample room for the laminator?
A work area must be established that allows for
operation in both the front and the rear of the
machine and provides space for efficient material
flow. Figure 2-1 shows a typical machine area
layout.
Is the environment appropriate for the laminator?
The laminator requires a clean, dust and vapor
free environment to operate properly. It must not
be located where there is air blowing directly on
the machine.
The operating environment must be free of
dust, flammable liquids and vapors. You can
be injured by inhaling chemical vapors. Vapor
build up or stored flammable liquids can cause
a fire. Excessive dust can damage the
laminator.
© GBC Pro-Tech 1997 October
CAUTION
WARNING
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
CAUTION
Do not locate the laminator where air is
blowing directly on the machine. The air flow
can cool the rolls unevenly and result in poor
quality output.
Has a certified electrician been contacted to both
wire the laminator and ensure that an adequate
power supply, having the appropriate capacity,
overcurrent protection, and safety lockouts is
available?
The laminator requires 220 to 240 VAC, 50/60
Hz, 55A, single phase 3 wire. Or, in Europe
only, 3-N phase 230/400 VAC, 50 Hz, 25A per
phase.
USA - For single phase 3 wire, L1, L2, and L3
are tied together with a jumper box or the main
terminal block.
Europe - For 3-N phase, L1, L2, and L3 are each
separate phases. The jumper box must be
removed on the main terminal block.
WARNING
Do not operate the laminator if the power
cord is damaged or frayed. You can be
severely shocked, electrocuted or cause a fire.
Contact a qualified electrician to replace the
cord.
WARNING
Do not allow anything to rest on the power
cord. Do not locate the cord where people can
walk on it. You or others can be severely
shocked, electrocuted or cause a fire.