Reading The Led; Fig. 3.2 - Disconnect 12 Vdc; Fig. 3.3 - Connect Blade Adapter; Fig. 3.4 - Connect Led - Norcold N1090 Series Service Manual

Compressor refrigerators
Table of Contents

Advertisement

Available languages

Available languages

Fig. 3.2 - Disconnect 12 VDC

3. Connect the blade adapter (
3
3
B

Fig. 3.3 - Connect Blade Adapter.

4. Connect the black LED wire
connect the red LED wire
.
(B)
4
4
A2

Fig. 3.4 - Connect LED

5. Connect the 12 VDC input wire
adapter blade
.
(B)
5
5
C

Fig. 3.5 - LED connection to control module

Reading the LED

If an error code is activated in the control module and the LED
is connected, it will fl ash a number of times. The number of
fl ashes will depend on what error was recorded. Each fl ash
will last 1/4 second and after the code is fl ashed there will be a
delay, then the code will repeat.
Write down all error codes; then refer to "Self-Test Diagnostic
Chart."