Cleaning The Instant System - Melitta Cafina CT8 Operating Instructions Manual

Hide thumbs Also See for Cafina CT8:
Table of Contents

Advertisement

2. Remove the tab holder (1) with a quarter turn coun-
terclockwise.
1
3. Insert a cleaning tablet (1) into the tab holder.
4. Turn the tab holder a quarter turn clockwise firmly
back into the machine (2).
5. Close the machine door.
6. Use the "Cleaning tablet is inserted" button to
confirm that a cleaning tablet has been inserted.
The machine starts the automatic cleaning pro-
cess.
The cleaning process takes a few minutes.
The machine is then switched off or depending on the
selection, it goes back to operational readiness mode.
Final activities
1. Clean the dispensing area once the automatic
cleaning process is complete (see chapter 8.10 on
page 34).
2. If you want to continue using the machine, refill the
milk as described in chapter 5.3.3 on page 12.
The milk and brewing system has been cleaned.
26288 • 20160202
2
Fig. 42: Cleaning tablet
Cleaning
8.6.3

Cleaning the instant system

Fig. 43: Removing the instant system cover
1. Open the instant system cover with the key (2).
2. Pull the cover (1) forwards.
3. Carry out the steps as described below.
Removing the mixer unit
1. Turn the powder chute (2) upwards so that no
powder can fall out.
2. Remove the instant container (1).
3. Remove the powder chute (2).
4. Remove the tube (6) on the mixer housing and on the
beverage outlet.
5. Turn the mixer flange (5) counterclockwise as far as
it will go.
6. Remove the entire mixer housing (4) towards the
front.
7. Remove the cover (3).
1
2
1
2
3
4
5
6
Fig. 44: Mixer unit
31
8

Hide quick links: