5.1
Time program for adjusting the heating
The purpose of this time program is to adjust the temperature
from the corresponding switching time. The control unit has the
following factory settings:
Switching time
06:30
Heating
20 °C
temperature
Table 3
▶ Select the "Heating"
▶ Press the selector.
Time program is displayed.
▶ Press the selector.
Mo-Fr is displayed.
▶ Turn selector if necessary to select a different time period.
The following time periods can be selected:
– Mo-Fr
– Sat-Sun
– Monday
– Tuesday
– Wednesday
– Thursday
– Friday
– Saturday
– Sunday
▶ Press the selector.
Time setting 1 is displayed. This is the time of the first
temperature change, e.g. the first heating phase of the day.
The hours display flashes.
▶ Turn the selector if necessary to set the hour.
▶ Press the selector.
The minutes display flashes.
▶ Turn the selector if necessary to set the minutes.
▶ Press the selector.
Temp. setting 1 is displayed. This is the temperature
following the time of the first temperature change, e.g. for
the first heating phase of the day.
The temperature indicator flashes.
▶ Turn the selector if necessary to set the temperature.
▶ Press the selector.
Time setting 2 is displayed.
The hours display flashes.
▶ Set Time setting 2 and Temp. setting 2.
▶ Set or deactivate Time setting 3 up to Temp. setting 6
( Chapter 5.3).
Comfort+ II RF – 6720886122 (2018/07)
08:30
16:30
22:30
16 °C
21 °C
10 °C
symbol in the main menu.
If a switching time is not used and no values are set:
▶ After the last temperature set, press the selector
repeatedly without making any further settings.
Example showing the adjustment of switching times:
•
Time setting 1, Temp. setting 1: time before getting up
and comfortable temperature for getting up.
•
Time setting 2, Temp. setting 2: time and temperature
after leaving the house.
•
Time setting 3, Temp. setting 3: time before returning
home and comfortable living temperature.
•
Time setting 4, Temp. setting 4: time after going to sleep
and temperature during the night until the next switching
time.
•
If more switching times are required, repeat procedure for
Time setting 5, Time setting 6 and Temp. setting 5,
Temp. setting 6.
5.2
Setting the DHW time program
The purpose of this time program is to adjust the DHW heating
switch-on/switch-off times. The control unit has the following
factory settings:
Switching time
06:30
Domestic Hot
ON
Water
Table 4
▶ Select the "DHW"
▶ Press the selector.
Time program is displayed.
▶ Press the selector.
Mo-Fr is displayed.
▶ Turn selector if necessary to select a different time period.
The following time periods can be selected:
– Mo-Fr
– Sat-Sun
– Monday
– Tuesday
– Wednesday
– Thursday
– Friday
– Saturday
– Sunday
▶ Press the selector.
DHW 1 on is displayed.
The hours display flashes.
▶ Turn the selector if necessary to set the hour.
Settings in the main menu
08:30
16:30
22:30
OFF
ON
OFF
symbol in the main menu.