WARNING
Electrical Shock Hazard
Turn power supply off before connect-
ing wires.
Use 8-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This cooktop must be connected to a
grounded, metallic permanent wiring sys-
tem or a ground connector should be
connected to the ground terminal or wire
lead on the cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Con-
nect the cooktop cable to the junction box
through the U.L. - or C.S.A.-listed conduit con-
nector. Complete electrical connection accord-
ing to local codes and ordinances.
Where local codes permit connecting the
frame-ground conductor to the neutral
(white) junction box wire (not used for Ca-
nadian installations):
1.
Disconnect the power supply.
2.
Connect the flexible, armored cable from
the cooktop to the junction box using a
U.L.- or C.S.A. -listed conduit connector
and tighten the screws on the conduit
connector.
3.
Connect the green (or bare) appliance
cable wire with the neutral (white) wire in
the junction box using a twist-on connec-
tor.
All manuals and user guides at all-guides.com

ELECTRICAL CONNECTIONS

4.
Connect the two black wires together;
then connect the two red wires together
with a twist-on connector.
red wires
white wire
bare or
green wire
cable from cooktop
Grounded Neutral
Where local codes do not permit connect-
ing the frame-ground conductor to the neu-
tral (white) junction box wire (used for all
Canadian installations):
1.
Disconnect the power supply.
2.
Connect the flexible, armored cable from
the cooktop to the junction box using a
U.L.- or C.S.A.-listed conduit connector,
and tighten the screws on the conduit
connector.
3.
Connect the two black wires together;
then connect the two red wires together
using a twist-on connector.
4.
Connect the green or bare ground wire
from the appliance cable to the grounded
wire in the junction box, or other grounded
connector using a twist-on connector.
5.
Install a twist-on connector on the end of
the white wire.
red wires
bare or
green wire
cable from cooktop
Ungrounded Neutral
2-2
cable from
power supply
junction box
twist-on
connector
black wires
U.L. or CSA-listed
conduit connector
cable from
power supply
junction box
white wire
twist-on
connector