Component Testing - KitchenAid KECC586G Manual

Built-in electronic touch-control ceramic cooktops
Table of Contents

Advertisement

COMPONENT TESTING

FAN
Fan
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
Test Procedure
Refer to page 3-4 for the procedure for servic-
ing the fan.
To test the fan, perform the following steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
Disconnect the wires from the fan termi-
nals.
3.
With no power applied, touch the leads of
the ohmmeter to the fan terminals. The
meter should indicate between 1500 and
1600 ohms.
All manuals and user guides at all-guides.com
Terminals
Wires
ELEMENTS
Terminal
Block
Limiter
Terminals
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in electrical
shock or other personal injury.
Test Procedure
Refer to page 3-5 for the procedure for servic-
ing the elements.
To test an element, perform the following steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
Disconnect the wires from the element
you wish to test.
3.
Touch the ohmmeter leads to the element
terminals. You should obtain the following
readings:
LF element:
1000 W = 58 Ω.
1400 W = 41 Ω.
LR element (1200 W) = 47 Ω.
RF element (1200 W) = 47 Ω.
RR element (1800 W) = 31 Ω.
4-1
Element

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kecc508gYkecc508gYkecc586g

Table of Contents