Type option, press Enter.
1=Display hardware resource information details
OPT Name
PCI/SCSI Location
--- ------ -------------------------- ------------------------- ----------------
0000:01:01.0.0/
0000:41:01.0.1/
sda
0000:41:01.0.1/0:3:0
sdb
0000:41:01.0.1/0:4:0
sdc
0000:41:01.0.1/0:8:0
sdd
0000:41:01.0.1/1:3:0
sde
0000:41:01.0.1/1:4:0
sdf
0000:41:01.0.1/1:5:0
0001:61:01.0.2/
sdg
0001:61:01.0.2/0:3:0
0001:61:01.0.2/0:6:0
sdi
0001:61:01.0.2/0:9:0
sdh
0001:61:01.0.2/255:0:0
0001:61:01.0.2/0:4:0
0001:61:01.0.2/0:5:0
e=Exit
q=Cancel
r=Refresh
Figure 26. Example Display Hardware Status
12. Look for the disk drive at the PCI location you recorded. The disk drive might have a failed status.
13. If the disk drive you want to replace is unprotected or in use, move the data from the disk drive
before continuing with this procedure.
For information, see the PCI-X SCSI RAID Controller Reference Guide for Linux.
14. Type option 1 (Display hardware resource information details) next to the disk drive you want to
replace. Press Enter.
A Disk Hardware Resource Information Details display similar to the following is shown.
Disk Unit Hardware Resource Information Details
Manufacturer . . . . . . . . . . . . . . : IBM
Product ID . . . . . . . . . . . . . . . : ST336607LC
Firmware Version . . . . . . . . . . . . : 43353048 (C50H)
Serial Number. . . . . . . . . . . . . . : 00006719
Capacity . . . . . . . . . . . . . . . . : 36.40 GB
Resource Name. . . . . . . . . . . . . . : /dev/sdd
Physical location
PCI Address. . . . . . . . . . . . . . . : 0001:50:01.0
SCSI Host Number . . . . . . . . . . . . : 2
SCSI Channel . . . . . . . . . . . . . . : 0
SCSI Id. . . . . . . . . . . . . . . . . : 4
SCSI Lun . . . . . . . . . . . . . . . . : 0
Extended Details
FRU Number . . . . . . . . . . . . . . . : 00P2676
Press Enter to Continue
e=Exit
q=Cancel
f=PageDn
Figure 27. Example Disk Hardware Resource Information Details display
15. Record the physical location information.
16. Return to the IBM Power RAID Configuration Utility display.
Display Hardware Status
Description
PCI-X SCSI Adapter
PCI-X SCSI Adapter
Physical Disk
Physical Disk
Physical Disk
Physical Disk
Physical Disk
Physical Disk
PCI-X SCSI RAID Adapter
Physical Disk
Advanced Function Disk
Physical Disk
RAID 10 Disk Array
RAID 10 Array Member
RAID 10 Array Member
t=Toggle
b=PageUp
Status
Operational
Operational
Active
Active
Active
Active
Active
Active
Operational
Active
Active
Active
Failed
Failed
Failed
More...