general information
EN
!
WARNING
Carbon monoxide poisoning may lead to death. Early signs of carbon monoxide poisoning resemble the fl ue,
with headache, dizziness, and/or nausea. If you have these symptoms, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some people - pregnant women, persons with heart or lung lisease,
anemics, those under the infl uence of alcohol, those at high altitutes - are more affected by carbon monoxide
than others.
The appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases.
Objects placed in front of the heater should be kept a minimum of 48" away from the front face of the appliance.
Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using non-listed
accessories and replacement parts (blowers, louvres, trims, gas components, vent components, etc.) could
result in a safety hazard and will void the limited lifetime warranty.
Not designed for use with a glass door. Screen must be closed when appliance is in operation.
This appliance must not be installed in a bedroom or bathroom.
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifi cs that apply to your area, for example in Massachusetts State:
This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of
Massachusetts.
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36" (91.4cm).
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
Un-vented room appliances shall be installed in accordance with 527 CMR 30.00 and 248 CMR 3.00
through 7.00.
Sellers of un-vented propane or natural gas-fi red space / room appliances shall provide to each purchaser a
copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/Webshare/
installation_manuals/mass_requirements.pdf
In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1 Installation
Code which can be obtained from:
American National Standards Institute Inc.
1430 Broadway
New York, NY 10018
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psig (35 mb). The appliance must be
isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (35 mb). When installed
with a blower or fan, the junction box must be electrically connected and grounded in accordance with local
codes. In the absence of local codes, use the current ANSI / NFPA 70 National Electric Code. In the case
where the blower is equipped with a power cord it must be connected into a properly grounded receptacle. The
grounding prong must not be removed from the cord plug.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location for
the appliance is in the center of a building, thereby allowing
the most effi cient use of the heat created. The location of
windows, doors and the traffi c fl ow in the room where the
appliance is to be located should be considered.
If the appliance is installed directly on carpeting, vinyl tile or
other combustible material other than wood fl ooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth.
note:
This does not apply to stoves.
Air shortage caused by an inadequate air supply, improper log positions, the addition of foreign or unapproved
materials or the failure to properly maintain the appliance, may result in incomplete combustion of the fuel.
6
W415-1966 / 07.08.19
or
National Fire Protection Association Inc.
Batterymarch Park
Quincy, MA 02269
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org