Download Print this page

Johnson Controls VP1000 Series Manual page 11

Pressure independent control valve

Advertisement

Flow rate settings | Réglages du débit | Ajustes del caudal | Einstellungen für
Durchflussmenge | Impostazioni della portata | Instellingen van de stroomsnel-
heid | Nastavení průtoku
Pre-setting the maximum flow | Préréglage du débit maximal | Ajustes del caudal
máximo | Voreinstellen des maximalen Du chflusses | Preimpostazione della
portata massima | Maximumdebiet van tevoren instellen | Přednastavení maximál
-ního průtoku
1
1
Table 5: VP10xHxx and VP10xJxx
VP10xHAA
Pre-setting
Flow l/h
9
150
8
133.5
7
114
6
99.5
5
85
4
71
3
55
2
39.5
1
19
0.5
9
0
0
2
2
VP10xHDA
VP10xHDC
VP10xJAJ
Flow l/h
Flow l/h
450
850
408
774
358
689
281
606
219
496
179
393
135
331
94
265
53
157
32
62.5
0
0
10
VP10xJDB
Flow l/h
Flow l/h
1000
1850
897
1734
782
1548
678
1320
564
1080
442
846
359
624
278
492
154
276
45
174
0
0
3
3