Download Print this page

Johnson Controls V43 Series Product/Technical Bulletin

Pressure actuated water regulating valve

Advertisement

Quick Links

V43 Pressure Actuated Water Regulating Valve
The V43 Pressure Actuated Water Regulating Valves
are designed to regulate water flow for water-cooled
refrigeration condensers requiring a large flow capacity
(100 to 1000 gallons per minute). These pilot operated
valves open on pressure increase and provide
modulating operation.
Built-in Pilot Valve
Easy Adjustment
Drain Plug
Mesh Monel Screen
© 1996 Johnson Controls, Inc.
Part No. 24-7664-699, Rev. —
Code No. LIT-125683
Features and Benefits
Allows for more precise throttling
May be serviced and adjusted without breaking
line connections
Allows water to be drained during shutdown to
reduce the possibility of freeze-up
Protects pilot valve from dirt, scale, etc. and is
easily removed for cleaning and servicing without
breaking any line connections
FANs 125, 121
Product/Technical Bulletin V43
Figure 1: V43 Pressure Actuated
Water Regulating Valve
Issue Date 0996
1

Advertisement

loading

Summary of Contents for Johnson Controls V43 Series

  • Page 1 Mesh Monel Screen Protects pilot valve from dirt, scale, etc. and is easily removed for cleaning and servicing without breaking any line connections Water Regulating Valve © 1996 Johnson Controls, Inc. Part No. 24-7664-699, Rev. — Code No. LIT-125683...
  • Page 2 pplication Overview etermining Valve Size The V43 water regulating valves are pilot operated, To select the correct valve size, first complete provide for modulating operation, and are available for Steps 1 through 3. These steps will determine the commercial and maritime applications. They are following variables: typically used to regulate water flow for condensers •...
  • Page 3 Step 2: Determine the Refrigerant Head Step 4: Select the Proper Valve Size. Pressure Rise Above the Valve Opening A properly sized valve meets the requirements of Point. the maximum water flow required, refrigerant head pressure rise above the valve opening point, and The refrigerant head pressure rise above the valve the water pressure available.
  • Page 4 (300 GPM) . Select valve type from Example: Table 3. In this example, the required flow for a R-22 system is 300 GPM. The desired system condensing temperature is 105°F. The refrigerant pressure at the outlet side of condenser is 211 psig.
  • Page 5 Figure 4: V43 Flow Capacity Charts V43 Pressure Actuated Water Regulating Valve Product/Technical Bulletin...
  • Page 6 Figure 5: Dimensions Table 1: Dimensions Reference 2 in. Valve 2-1/2 in. Valve 3 in. Valve 4 in. Valve Letter in. (mm) in. (mm) in. (mm) in. (mm) 9-1/2 (241) 10-3/4 (273) 11-3/4 (298) 14 (356) 7-1/2 (191) 8 (203) 9 (229) 10-3/4 (273) 4-3/4 (121)
  • Page 7 nstallation and Initial Adjustment Note: If available, follow the mounting instructions of 7. Put the system into operation under normal the equipment onto which the V43 will be operating conditions. installed. For new installation, a companion 8. Determine the correct refrigerant operating head flange and gasket kit (refer to Table 3) is pressure for the system.
  • Page 8 alve Adjustment Make adjustments gradually. Adjust by 1/2 5. After flushing the V43, remove the screwdriver revolution and wait for the system to stabilize after and set the adjusting screw to the desired operating pressure. (Refer to the Valve each adjustment change. The differential is not adjustable.
  • Page 9 Commercial service with iron body, open on section for instructions. To obtain replacement parts, pressure increase contact the nearest Johnson Controls distributor. Replacement parts are listed in V43 Series Repair Maritime service with brass body, open on Parts Kits (LIT-121690). pressure increase...
  • Page 10 Table 4: Optional Flange and Gasket Kits* Water Valve Shipping Weight Number Size lb. (kg) KIT14A-613 2 in. 11.8 (5.4) KIT14A-614 2-1/2 in. 16.5 (7.5) FLG15A-600 3 in. 20 (9.1) FLG15A-601 4 in. 34 (15.4) A companion flange and gasket kit is required to mount the water lines to commercial type V43 water regulating valves.
  • Page 11 Notes V43 Pressure Actuated Water Regulating Valve Product/Technical Bulletin...
  • Page 12 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.