WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics found on pullout labels attached
to the gas valve located within the control compartment. Two Millivolt wiring diagrams are provided here, one each for both Honeywell and SIT
equipped systems.
Electronic Wiring Diagram (Honeywell)
(Optional ON/OFF Switch Wiring)
1. If any of the original wire as supplied must be replaced,
1.
it must be replaced with Type AWM 105 C – 18 GA.
wire.
2. 120V, 60Hz – Less than 3 amps.
Gas Valve
PILOT
CONTROL
ASSEMBLY
BK
R
BL
W
BL
R
BK
WHT
BK
OPTIONAL
ON/OFF SWITCH
OR
WALL SWITCH
Factory Wired

WARRANTY

Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the warranty
accompanying this manual. Please read the
warranty to be familiar with its coverage.
Retain this manual. File it with your other
documents for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 800-731-8101
Your Fireplace's Model Number _______________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed __________________________
The Type of Gas Your Fireplace Uses ___________________________________
Your Dealer's Name _________________________________________________
8
If any of the original wire as supplied must be replaced, it
must be replaced with Type AWM 105 C – 18 GA. wire.
OPT. ACCESSORY
SWITCH
BK
120
BK
W
VAC.
G
G
Break
BK
Off Tab
To Opposite Side
Junction Box
* For Wall Switch Attachment Only.
Transf.
B
120 V.
G
24 V
BK
BK
LIMIT
SWITCH
Field Wired

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
SIT Millivolt Wiring Diagram
Limit Switch
BK
Thermopile
WHT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Honeywell Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105 C – 18 GA. wire.
WHT
BK
TH
TH
TPTH
TP
Limit
Switch
TH
T P
TP
Thermopile
BK
* For Wall Switch Attachment Only.
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor. For the name of your nearest distribu-
tor contact:
LHP
1110 West Taft Avenue • Orange, CA
92865
BK