CONGRATULATIONS!
In selecting this SUPERIOR B-vented gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied SUPERIOR
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.

TABLE OF CONTENTS

Introduction ..................................... page
General Information ......................... page
Combustion Air Controls ................. page
Maintenance .................................... page
Manual Limit Switch ........................ page
Log Placement ................................. page
Maintenance Schedule ..................... page
Wiring Diagrams .............................. page
Warranty .......................................... page
Replacement Parts .......................... page
Replacement Parts List ..................... page 16
Accessory Components ................... page 18

INTRODUCTION

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.
The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.
2
These appliances comply with National Safety
Standards and are tested and listed by War-
nock Hersey (Report No. J20006722) to ANSI
2
Z21.50 - 2000 (in Canada, CSA 2.22 - 2000),
2
and CAN/CGA-2.17-M91 in both USA and
Canada, as vented gas fireplaces.
3
4
Installation must conform to local codes. In
the absence of local codes, installation must
5
comply with the current National Fuel Gas
5
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.)
6
6
Electrical wiring must comply with local codes.
In the absence of local codes, installation must
7
be in accordance with the National Electrical
6
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)
8
8
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
8
ITS COMPONENTS. ANY MODIFICATION OR
8
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'apareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.
WARNING: THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade the
performance of this system and may be dan-
gerous.
Input of appliance is 15,000 BTU/HR.
Gas
Orifice
Type
Size
Elevation
#49
0 - 4500'
Natural
(.073)
(0 - 1370 m)
0 - 4500'
Propane
(.045)
(0 - 1370 m)
Nominal operating pressures for the manifold
side of the gas control system are; 3.5 inches
water column (0.87 kPa) for natural gas mod-
els and 10 inches water column (2.49 kPa) for
propane gas models.
Do not use these appliances if any part has
been under water. Immediately call a quali-
fied, professional service technician to in-
spect the appliance and to replace any parts of
the control system and any gas control which
have been under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'leau.