Superior B-40REN Homeowner's Care And Operation Instructions Manual

Standard series 36" b-vented gas appliances
Hide thumbs Also See for B-40REN:

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WH Report No. J20006722
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
STANDARD SERIES
36" B-VENTED GAS APPLIANCES
P/N 725,008M REV. F 05/2004
MODELS
Millivolt Models
B-40RMN
B-40RMP
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
Electronic Models
B-40REN
B-40REP
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior B-40REN

  • Page 1 • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies. L'installation et service doit être exécuté par un qualifié installeur, agence de service ou le fournisseur de gaz. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Electronic Models B-40REN B-40REP...
  • Page 2: Table Of Contents

    CONGRATULATIONS! In selecting this SUPERIOR B-vented gas appliance you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied SUPERIOR Fireplace Owners.
  • Page 3: Operation/Care Of Your Appliance

    Millivolt appliances may be fitted at time of manufacture with either a Honeywell millivolt gas control valve or as SIT millivolt gas control valve. Both valves have been tested with and approved for use with these appliances and are listed accordingly. Test gage connections are provided on the front of the millivolt gas control valve (iden- tified IN for the inlet and OUT for the mani-...
  • Page 4: Combustion Air Controls

    SIT Millivolt Valve Gas Control Knob Spark Ignitor Gas Control Knob Honeywell Millivolt Valve Figure 2 Honeywell Electronic Gas Valve Figure 3 If the appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch.
  • Page 5: Maintenance

    Combustion Air Actuator Remove Locking Screw and “Pop” Actuator to the Left Before Initial Use Pull Forward to Open, Push Back to Close Figure 6 If your screw is not removed and you have reason to believe that you have a complete outside combustion system, contact your dis- tributor to have your appliance inspected for the presence of the complete system.
  • Page 6: Millivolt Appliance Checkout

    Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top " (9 mm) at the pilot generator (ther- mopile) should be engulfed in the pilot flame. The flame should project 1"...
  • Page 7: Maintenance Schedule

    Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Inspecting/Cleaning Burner, Logs and Controls Check Flame Patterns and Flame Height Inspecting/Cleaning Pilot and Burner Checking Vent System Appliance Checkout Periodically (After the Burning Season) Maintenance Task Cleaning Firebox Interior Check Flame Patterns and Flame Height Checking Vent System Cleaning Optional Glass Doors...
  • Page 8: Wiring Diagrams

    WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics found on pullout labels attached to the gas valve located within the control compartment. Two Millivolt wiring diagrams are provided here, one each for both Honeywell and SIT equipped systems.
  • Page 9 NOTES: NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 10: Lighting Instructions - Millivolt

    LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo ignitor.
  • Page 11 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 12: Lighting Instructions - Electronic

    WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
  • Page 13 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 14: Troubleshooting Guide - Millivolt

    TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM 1.
  • Page 15: Troubleshooting Guide - Electronic

    TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM ote: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES 1.
  • Page 16: Replacement Parts List

    *10. *11. **15. **16. *Appliances may be fitted at the factory with either a Honeywell or SIT Millivolt gas control valve. **For SIT gas valve equipped appliances only. REPLACEMENT PARTS LIST DESCRIPTION Gas Fireplace Assembly Firescreen Rod, Screen Front Log Rear Log Burner Log Grate...
  • Page 17 REPLACEMENT PARTS NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 18: Accessory Components

    ACCESSORY COMPONENTS Remote Control System (Standard) H0249 Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all hardware re- quired to install the unit.
  • Page 19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2001 by Lennox Hearth Products P/N 725,008M REV.

This manual is also suitable for:

B-40repB-40rmnB-40rmp

Table of Contents