Design information

DHW cylinder selection tables

DHW cylinders with "-W" in the product name are supplied with a
white finish. Appliances with "-B" or "-V" in the product name are
supplied in Vitosilver (marked in grey in the table).
Vitodens 200-W gas system boilers, cylinder allocation
Rated heating output range [kW]
Vitocell 100-W (type CUGA, CUGA-A) below the boiler
Vitocell 100-W (type CVA, CVAA, CVAA-A) adjacent to
the boiler
Vitocell 100-V (type CVA) adjacent to the boiler
Vitocell 200-W (type EVIA-A) adjacent to the boiler
Vitocell 300-V (type EVIA-A) adjacent to the boiler
Vitocell 100-W (type CVB, CVBB) adjacent to the boil-
er, dual mode
Vitocell 100-W (type CVUB) adjacent to the boiler, dual
mode
Vitocell 100-W (type CVUC-A) adjacent to the boiler,
dual mode (for Vitodens 200-W only)
Vitocell 100-B (type CVB) adjacent to the boiler, dual
mode
Vitocell 300-B (type EVBA-A) adjacent to the boiler,
dual mode
Vitocell 340-M (type SVKC) heating water buffer cylin-
der with DHW heating
Vitocell 360-M (type SVSB) heating water buffer cylin-
der with DHW heating
8.3 Connections on the water side

Connection on the DHW side

Vitodens 200-W gas condensing combi boiler
For the DHW connection, connection sets for surface or flush mount-
ing are available as accessories. The instantaneous water heater
provides direct DHW heating.
If used in conjunction with galvanised pipes, note that the instanta-
neous water heater is designed as a stainless steel plate heat
exchanger with copper solder joints (observe the flow rule).
In existing installations (modernisation projects), the risk of electro-
lytic corrosion is low, since a protective layer will have formed on the
inside of the pipes.
VITODENS
(cont.)
Practical cylinder allocation (cylinder capacity in litres)
up to 19.0
120
150
160
200
300
160
200
300
400
300
300
300
708/30
708/30
25.0
120
150
160
200
300
160
200
300
500
300
400
300
300
500
300
500
708/30
708/30
If DHW is to be drawn simultaneously from several points, we rec-
ommend the installation of a separate DHW cylinder in conjunction
with the gas system boiler (see "Decision making aids regarding
DHW heating").
With water hardness of 20 °dH and higher, we recommend the use
of a water treatment system in the cold water line when heating
DHW.
32.0
120
150
160
200
300
500
160
200
300
500
300
400
300
300
500
300
500
708/30
708/30