ESD Guidelines
Electrostatic charging
Every person without a conductive connection to the electrical potential of his/her
surroundings can be electrostatically charged.
The figure below shows the maximum electrostatic charge that can build up on a person
coming into contact with the materials indicated. These values correspond to IEC 801-2
specifications.
Figure 9-1
Basic protective measures against electrostatic discharge
● Ensure good equipotential bonding:
● Avoid direct contact:
● (e.g. during maintenance work). Handle the modules without touching any chip pins or
28
Electrostatic voltages on an operator
When handling electrostatic sensitive devices, ensure that your body, the workplace and
packaging are grounded. This prevents electrostatic charge.
As a general rule, only touch electrostatic sensitive devices when this is unavoidable
PCB traces. In this way, the discharged energy can not affect the sensitive devices.
Discharge your body before you start taking any measurements on a module. Do so by
touching grounded metallic parts. Always use grounded measuring instruments.