Commissioning

7.6 Inserting the connection key on the IPC

Procedure
1. Set the recovery points for both partitions of the IPC. Additional information is provided in
Chapter Setting recovery points (Page 29).
2. Then perform all security-relevant Windows updates.
Additional information
Additional information on handling Windows updates is provided in the following chapters:
● Windows Security Center (Page 21)
● Updating Windows (Page 42)
● Activating/deactivating the service mode (Page 41)
7.5

Setting up the IP address (optional)

The IPC requires an IP address in your company network to operate the connectivity module
and to establish the connection to SIDRIVE IQ.
The LAN interface "X1 P1" of the IPC to connect with the Internet is configured as DHCP client
(Dynamic Host Configuration Protocol). The LAN interface automatically sources an IP address
from the next accessible DHCP server. When required, via a Remote Desktop Connection, you
can deactivate DHCP for the LAN interface "X1 P1" and assign a fixed IP address.
See also
Prerequisites (Page 19)
7.6
Inserting the connection key on the IPC
To log in to the connectivity module with SIDRIVE IQ, insert the connection key on the IPC in
"MindConnect Bridge".
Prerequisites
● A Remote Desktop Connection has been established from the local service PC to the IPC.
● The IPC is connected with the Internet.
● You have received the email with the connection key for the connectivity module, and have
opened this on the local service PC.
Carefully note that the connection key is only valid for 7 days. After the validity expires, the
connection key can no longer be used to log in the connectivity module with SIDRIVE IQ.
30
SINAMICS CONNECT 500
Operating Instructions, 10/2019