Progress Of Charging - Canon ZR70 MC A Service Manual

Mini dv digital video cassette, ntsc
Hide thumbs Also See for ZR70 MC A:
Table of Contents

Advertisement

3-2-2 Progress of Charging

When the conditions described in 3-2-1 are satisfied, the MODE MI-COM starts charging according to the specifications in Fig.2-5.
The charging current in quick charge can be restricted by CA-570.
* Charging is allowed to start provided that the UNREG voltage is 8.4 0.3V before
starting the charging. Otherwise, an error is indicated.
* Charging can be performed provided that the power is turned OFF.
* If the DC JACK is detected, the charging is turned OFF when the power is turned ON
(no power supplied from the battery).
LED flashes once
Quick charge 1.525A 0.075A
When battery voltage
becomes
quick charge starts.
* An error is indicated and charging is turned OFF if the battery voltage becomes 6.4V
or lower during charging other than trickles 1 and 2.
* An error is indicated and charging is turned OFF if the battery voltage becomes 5V
or lower during charging trickle 2.
* An error is indicated and charging is turned OFF if the charging voltage is 1.8A or higher
(detected voltage > 2.7V).
* Charging is turned OFF if the charging current is 70mA or lower.
If the battery voltage
becomes
the trickle 2 starts.
350mA max.
Trickle 1
50mA max.
BATT V 5.2V
INIT-CHG1 ON
INIT-CHG2 OFF
CHG
OFF
Torque 1 timer
110 min. max.
Error indicated and
charging OFF at timeout
5.2V BATT V 6.5V
INIT-CHG1 ON
INIT-CHG2 ON
CHG
OFF
Torque 2 timer
100 min. max.
Error indicated and
charging OFF at timeout
LED flashes twice
1.1A
ADI detection voltage
6.5V,
= 1.706V
5.2V,
TOTAL TIMER
BATT V 6.5V
BATT V 6.5V
ADI detection voltage
0.155V ADI detection voltage
1.706V
INIT-CHG1 OFF
INIT-CHG1 OFF
INIT-CHG2 OFF
INIT-CHG2 OFF
CHG
ON
CHG
Quick charge timer
2-flash timer
Error indicated and
LED lit and charging ended at
charging OFF at timeout
timeout
BP-Z : 2Hmax
BP-Z : 2Hmax
BP-2Z : 4Hmax
BP-2Z : 4Hmax
BP-3Z : 5Hmax
BP-3Z : 8Hmax
Total timer
LED lit and charging ended at
timeout
BP-Z : 6Hmax
BP-2Z : 9Hmax
BP-3Z : 12Hmax
Fig. 2-5
CHAPTER 2. TECHNICAL DESCRIPTION
Up to battery installed/removed
If the battery is not installed/removed
after completion of charge, charging
does not start unless the battery voltage
becomes 7V or lower.
Specified from D65
BP-Z: 10 min.
BP-2Z: 10 min.
BP-3Z: 10 min.
100mA
ADI detection voltage
= 0.155V
1.706V
ON
BATT V 8.0V
0.109V ADI detection voltage 0.155V
INIT-CHG1 OFF
INIT-CHG2 OFF
CHG
Supplementary timer
LED lit and charging ended at
timeout
BP-Z : 1Hmax
BP-2Z : 1Hmax
BP-3Z : 1Hmax
2-9
ZR70 MC A, ZR65 MC A, ZR60 A
LED lights up steadily
and power turned ON
70mA
ADI detection
voltage
= 0.109V
Lapsed time
Charge
ended
BATT V 8.0V
ADI detection voltage
0.109V
INIT-CHG1 OFF
INIT-CHG2 OFF
CHG
OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zr65 mc aZr60 a

Table of Contents