Ⅲ . Assembly procedure of main body

1. Battery Chamber and Related Parts

① A13 (A14 (4pcs.), A15 (2pcs.))
② 0-T900
③ TY-CNL-D1.7x4.0
④ Solder 4 lands.
⑤ Fold down T907 as instructed in the figure (2 places) and stick it on A13 by using DT (8x18).
⑥ Solder 2 lands of T907.
⑦ Solder 7 lead wires with arranging the lead wires as shown in the figure below.

2. 0-E000 (Shutter Block)

① Put A2 on the main plate.
② A65 x4 (Screw)・・・A2 must be installed in place.
③ 0-E000・・・ Confirm there is neither dust nor scratch on 0-E000.
④ A71 x2 (Shoulder screw)
⑤ TY-CNL-D1.7x2.5・・・Make sure 0-E000 is installed securely.
⑥ Put A13 on the main plate.
⑦ TY-CNL-D1.7x4.0 (2pcs)
⑧ CNL-D1.7x2.5 (2pcs.)
Green
Yellow
Black
Black
76180 EM -26/73-
A14
A13
Blue
White
Brown
A15