Auxilary Functions

1
CVBS (option)
Scrip
Light
Breaker
2
Power on
TP
Ext 1
E
3
1
Call button
1
Pressing this momentary button sends a signal to the
control panels calling for attention.
2
Script Light connector
2
A 3-pole socket which supplies +12 Vdc for a script
light (maximum dissipation 0.25A). The optional
script board (LDK 6985/15) is connected to this
socket.
3
Teleprompter output socket
3
This BNC conector supplies the 1Vpp teleprompter
signal applied to the base station.
(This socket has no output if the reference input
socket is used as a return video channel).
Location of Controls and Functions
Eng
Front
Off
Prod
Rear
Loc
Ext
Mix
Call
Mic
VF
Ext
Front Rear 48V
DC in
48V On
Operator's Manual LDK 200 Triax
Tracker
Aux
4
REF
IN
6
4
Aux connector
4
This 11-pole female socket provides analogue control
signals and facilities for the connection of a
private data channel (see installation manual).
5
Tracker connector
5
This 11-pole female socket provides full intercom and
signalling facilities for the dolly or crane driver
(see installation manual).
6
Reference input socket
6
This BNC conector is used to supply a 1Vpp reference
signal to the camera for genlocking when the
optional encoder (LDK 5435) is fitted.
This connector can be used as an input socket for a
1Vpp CVBS signal which is output on the TP
out connector of the Base Station. This is only
possible with Base Station type LDK 4501 and
when the optional encoder (LDK 5435) is fitted.
Select the function of this socket in the Install menu
of the camera or the System menu of the Base
Station.
5
4-13