OUTDOOR UNITS INFORMATION

Chassis
External
Apperance
Outdoor Fan
2 FAN
Phase
PFC
PFC
ARUN40LS2A
Heat
ARUN50GS2A
ARUV50LS2A
Pump
ARUN60GS2A
ARUN60LS2A
Model
ARUV40LS2A
Cooling
ARUV60GS2A
ARUV50LS2A
Only
ARUV60LS2A
CAUTION
!
• Ratio of the connectable Indoor Units to the Outdoor: Within 50
~ 130%
• Ratio of running Indoor Units to the Outdoor: Within 10 ~ 100%
• A combination operation over 100% cause to reduce each in-
door unit capacity.
Power Supply : 1Ø, 220~240V, 50Hz / 1Ø, 220V, 60Hz
Heat Pump Model
Chassis
System(HP)
ARUN40GS2A
Model
Product charge
kg
Refrigerant
CF(Correction Factor) kg
Max. Connectable No. of Indoor Units
Net Weight(Gross Weight)
kg
mm
Dimensions(WxHxD)
37.4×32.8×13.0 37.4×54.3×13.0 37.4×54.3×13.0
inch
mm
Liquid Pipes
inch
Connecting
mm
Pipes
Gas Pipes
inch
Connection Type
Cooling Only Model
Chassis
System(HP)
Model
Product charge
kg
Refrigerant
CF(Correction Factor) kg
Max. Connectable No. of Indoor Units
Net Weight(Gross Weight)
kg
mm
Dimensions(WxHxD)
37.4×32.8×13.0 37.4×32.8×13.0 37.4×54.3×13.0
inch
mm
Liquid Pipes
inch
Connecting
mm
Pipes
Gas Pipes
inch
Connection Type
U3
U4
1 FAN
PFC
Active Filter
PFC
ARUN40LS2B
ARUN50LS2B
ARUN40GS2A
ARUN60LS2B
ARUV40LS2B
ARUV50GS2A
ARUV50LS2B
ARUV40GS2A
ARUV60LS2B
U4
U3
4
5
ARUN50GS2A
ARUN60GS2A
1.8
3.0
0
0
6
8
77
106
106
950×834×330
950×1380×330 950×1380×330
9.52
9.52
9.52
3/8
3/8
15.88
15.88
19.05
5/8
5/8
FLARE
BRAZING
BRAZING
U4
U4
4
5
ARUV40GS2A
ARUV50GS2A
ARUN60GS2A
1.95
1.95
0
0
6
8
78
78
106
950×834×330
950×834×330
950×1380×330
9.52
9.52
9.52
3/8
3/8
15.88
15.88
19.05
5/8
5/8
FLARE
FLARE
BRAZING
Power Supply : 3Ø, 380~415V, 50Hz/ 3Ø, 380V, 60Hz
Chassis
System(HP)
Model
Product charge
Refrigerant
CF(Correction Factor) kg
Max. Connectable No. of Indoor Units
Net Weight(Gross Weight)
Dimensions(WxHxD)
Liquid Pipes
Connecting
Pipes
Gas Pipes
Connection Type
Connectable Indoor Unit
should be connected with "2 series" indoor unit only.
Ex) ARNU07GSEA2

BEFORE INSTALLATION

Environment-friendly Alternative Refrigerant
R410A
The refrigerant R410A has the property of higher operating pressure in
comparison with R22.
Therefore, all materials have the characteristics of higher resisting
U3
pressure than R22 ones and this characteristic should be also consid-
ered during the installation.
6
R410A is an azeotrope of R32 and R125 mixed at 50:50, so the ozone
depletion potential (ODP) of R410A is 0. These days the developed
3.0
countries have approved it as the environment-friendly refrigerant and
0
encouraged to use it widely to prevent environment pollution.
9
CAUTION
!
• The wall thickness of the piping should comply with the relevant
local and national regulations for the designed pressure 3.8MPa
3/8
• Since R410A is a mixed refrigerant, the required additional re-
frigerant must be charged in its liquid state.
3/4
• If the refrigerant is charged in its gaseous state, its composition
changes and the system will not work properly.
• Do not place the refrigerant container under the direct rays of
the sun to prevent it from exploding.
• For high-pressure refrigerant, any unapproved pipe must not be
U3
used.
6
• Do not heat pipes more than necessary to prevent them from
softening.
• Be careful not to install wrongly to minimize economic loss be-
3.0
cause it is expensive in comparison with R22.
0
9
3/8
3/4
*A:PFC model, B:Active Filter model
U3
U3
4
5
ARUN40LS2*
ARUN50LS2*
kg
ARUV40LS2*
ARUV50LS2*
3.0
3.0
-0.5
0
6
8
kg
107
107
mm
inch
950 x 1,380 x 330 950 x 1,380 x 330 950 x 1,380 x 330
37.4 x 54.3 x 13.0 37.4 x 54.3 x 13.0 37.4 x 54.3 x 13.0
mm
inch
Ø9.52
Ø9.52
3/8
3/8
mm
inch
Ø15.88
Ø15.88
5/8
5/8
U3
6
ARUN60LS2*
ARUV60LS2*
3.0
0
9
107
Ø9.52
3/8
Ø19.05
3/4