Mounting The Boiler And Making Connections; Removing The Front Panel And Mounting The Boiler; Fitting The Connections On The Water Side - Viessmann VITODENS 111-W Installation And Service Instructions Manual

4.7 to 35.0 kw gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

Mounting the boiler and making connections

Removing the front panel and mounting the boiler

Note
When mounting on a wall, please note: Weight without
packaging is approx. 65 kg.
2.
Fig. 4
1. Undo the screws on the underside of the boiler; do
not remove them completely.
2. Remove front panel.
3. Hook the boiler into the wall mounting bracket.

Fitting the connections on the water side

For installation of fittings on the heating water
side and DHW side, see separate installation
instructions.
3.
1.
2x
4. Take the additional type plate from the documenta-
tion supplied with the boiler.
In consultation with the system user, attach the
additional type plate to the outside of the appliance
in a position visible to the flue gas inspector.
!
Please note
To prevent appliance damage,
connect all pipework free of load and torque
stress.
Installation sequence