Bosch Climate 5000 RAC 2,6-2 OU Installation Manual page 3

Split-type room air conditioner
Table of Contents

Advertisement

7. The appliance should not be installed in a room with a continuous
heat source (for example: open flames, an operating gas appliance
or an operating electric heater)
8. Do not pierce or burn the unit.
9. Appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.
10. Be aware that refrigerants may not contain an odour.
NOTICE:
Clause 7 to 10 are required for the units that adopt R32 refrigerant.
WARNING
11. For all electrical work, follow all local and national wiring
standards, regulations and the Installation Manual. You must use
an independent circuit and single outlet to supply power. Do not
connect other appliances to the same outlet. Insufficient electrical
capacity or defects in electrical work can cause electric shock or
fire.
12. For all electrical work, use the specified cables. Connect cables
tightly and clamp them securely to prevent external forces from
damaging the terminal. Improper electrical connections can
overheat and cause fire and electric shock.
13. All wiring must be correct to ensure that the control board cover
can close properly. If the control board cover is not closed properly,
it can lead to corrosion and cause the connection points on the
terminal to heat up, causing fire or electrical shock.
14. In certain functional environments, such as kitchens, server rooms,
etc., the use of specially designed air-conditioning units is highly
recommended.
15. If the supply cable is damaged, it must be replaced by Qualified
Personnel in order to avoid a hazard.
CAUTION
For units that have an auxiliary electric heater, do not install the unit
within 1 metre of any combustible materials.
Do not install the unit in a location that may be exposed to
combustible gases. If combustible gas accumulates around the unit,
it may cause fire.
Do not operate your air conditioner in a wet room such as a bathroom
or laundry room. Exposure to water can cause electrical components
to short circuit.
1. The product must be properly grounded at the time of installation,
otherwise electric shock may occur.
2. Install drainage piping according to the instructions in this manual.
Improper drainage may cause water damage to your home and
property.
3. The appliance shall be stored so as to prevent mechanical damage
from occurring.
4. Any person working on the refrigerant circuit should hold a current
valid certificate from an industry-accredited assessment authority,
which authorizes their competence to handle refrigerants safely in
accordance with an industry recognized assessment specification.
Climate 5000 – 6720886909 (2018/04)
Note on Fluorinated Gasses
1. This air-conditioning unit contains fluorinated gasses. For specific
information on the type of gas and the amount, please refer to
the relevant label on the unit itself. Compliance with national gas
regulations shall be observed.
2. Installation, service, maintenance and repair of this unit must be
performed by qualified personnel .
3. Deinstallation and recycling of the product must be performed by
qualified personnel.
4. The system must be checked every 12 months for leaks. This should
be carried out by a qualified personnel.
Safety Precautions
3