7NG3213
Different codings for the respective quality specification.
Dec
Hex
Cause
04
04
Parameters do not match. Dynamic
value is incorrect.
15
0F
Device error detected, e.g. memory
error. The transmitter is switched off
with certain memory errors.
16
10
Connected sensor shows error.
17
11
Short-circuit detected.
18
12
Open circuit or sensor break
detected.
1)
31
1F
1)
Transmitter out of order. Parameterizable equivalent value behavior.
Three cases can be selected:
2)
Depending on the parameterization, the transmitter is in a certain state which requires an
adapted procedure:
1. and 2.: The transmitter is out of order. Clear the cause of the error or re-paramterize the
equivalent value behavior and switch the state to automatic.
3. Analyze the bad value/status.
Table 1
Status coding for "Poor quality"
66
Status coding for "Poor quality"
1. Through connect parameterized equivalent value.
2. Hold last valid value (default value).
3. Through connect bad value/status
Instruction Manual
Measure
Check the parameters.
Change the transmitter.
Check wiring and sensor.
Check wiring to sensor.
Check wiring and sensor.
2)
C79000-B7174-C55-04
SITRANS T3K PA