(4) Connect the drain hose.
Do not enforce the base of the drain hose when making a connection.
● Insert securely the drain hose into the PVC pipe.
● When installing the drain hose extension, connect with an optional drain hose.
After connection, bundle with armoring tape.
● Make sure not to make the drain hose trapped.
Insulate the connected part of the drain hose with the tubing insulation and check whether or not the water drains.
PVC pipe
(VP-16)
(5) When there is a long horizontal drain hose runs with very little slope to the run, water is likely to remain inside the hose. Slant the
drain hose downward slightly to the outdoors and insulate it with the insulation.
● Slant downward not to remain water inside the drain hose.
● Make sure tubing does not become trapped.
● Do not let the tip of the drain hose dip into the drain water.
● Do not leave the drain hose in the sewerage. This will cause the heat exchanger erosion damage caused by the corrosive gas such
as hydrogen sulfide occurred inside the sewerage and lead to a gas leak.

3-5. To mount and unmount indoor unit

How to mount indoor unit
1. To install the indoor unit, mount the indoor unit onto the tabs on the upper part of the installation plate.
2. Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the
lower part of the installation plate.
3. Close the front panel and ensure that the panel is perfectly stable.
How to unmount indoor unit
Press the 2 PUSH marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount.
In the case of using
PVC pipe (VP-16)
Wall
Indoor side
Drain hose ø16 mm
Slant
downward
Tabs
Tabs
Installation plate
2 Remove
1 Push by both hands.
In the case of using
PVC pipe (VP-30)
Over 700 mm
PVC pipe
(VP-20)
Trap
Trap
Push by both hands.
Installation plate
Tabs
Connecting part
12
Wall
Indoor side
Drain hose ø16 mm
PVC pipe (VP-30)
Adhere with PVC adhesive.
Reducing adaptor (30×20)
Installation plate
Tabs
Connecting part