= two-digit seconds.
<ss>
= carriage return character.
<CR>
= line feed character.
<LF>
For example, to display the date and time, send:
F3<CR>
XLi responds:
F3 UTC
01/01/2002 00:05:34<CR><LF>
To set the time and date, send:
F3 UTC 07/14/2002 18:20:30<CR>
Only valid times and dates are accepted. The XLi responds:
OK<CR><LF>
F4 – Serial Port Configuration
Use function F4 to change or display the serial port settings. The factory settings are:
Interface – RS-232
Baud rate – 9600
Data bits – 8
Parity – NONE (only available/valid when Data Bits is set to 8)
Stop bits – 1
Command Line
To display the Serial Port settings, send:
F4<CR>
XLi responds:
F4<S><RS><SEP><BR><SEP><DB><SEP><P><SEP><SB><CR><LF>