Buffer Data; Clear Transmission Buffer - Symbol LS 2106 Product Reference Manual

Rs-232/synapse/keyboard wedge scanner
Hide thumbs Also See for LS 2106:
Table of Contents

Advertisement

LS 2106 Product Reference Guide

Buffer Data

To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space
immediately following the start pattern.
t
Unless symbol overflows the transmission buffer, the unit gives a lo/hi beep to
indicate successful decode and buffering. See
t
Unit adds the message, excluding the leading space to the transmission buffer.
t
No transmission occurs.

Clear Transmission Buffer

To clear the transmission buffer, read a symbol which contains only a start character, a dash
(minus), and a stop character.
t
Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased,
and no transmission has occurred.
t
Unit erases the transmission buffer.
t
No transmission occurs.
4-32
Overfilling Transmission
CLEAR BUFFER