Setting procedure
1. Turn off the power of the IXS-6700/IXS-6600.
2. Connect the PC to the REMOTE3 connector.
3. Set the S1204 of the main CPU (CA-65) board to "E".
4. Turn on the power of the IXS-6700/IXS-6600.
5. The following image is displayed on the PC screen.
IP ADRS M = 192.168.0.135
IP ADRS B
= 192.168.0.136
GROUP ID
= 129
TERM PORT = 1001
LOG PORT = 8001
DEF GWAY = 192.168.0.254
SNET MASK = 255.255.255.0
OPT IP
= 192.168.0.136
OPT1 PORT = 8002
OPT2 PORT = 8003
OPT3 PORT = 0
TERM T OUT= 10
SNMP TRAP1
= 192.168.0.1
SNMP TRAP2
= 192.168.0.2
GMT (+)
= 09
Contact
=
Name
=
Location
=
UNIQUE No =
IP ADRS M :
IP address of the CPU board on the main CPU that is enabled when S1202-4 is ON.
IP ADRS B :
IP address of the CPU board on the backup CPU that is enabled when S1202-4 is ON.
GROUP ID :
Group ID that is enabled when S1202-4 is OFF.
TERM PORT : Port number of the terminal (normally do not change)
LOG PORT :
Port number of the log (normally do not change)
DEF GWAY :
Default gateway value
SNET MASK : Subnet mask value
OPT IP :
IP address of the upper level controller (*1) to be connected via Ethernet
OPT1 PORT :
TCP/IP port of the upper level controller (*1) to be connected via Ethernet
OPT2 PORT :
UDP port of the upper level controller (*1) to be connected via Ethernet
OPT3 PORT :
Command transmission port of the controller or the IXS series to be connected via
Ethernet
TERM T OUT : Timeout time when the terminal is connected via Ethernet.
0 to 999 (Unit: minute). Does not timeout when 0 is input.
SNMP TRAP1 : SNMP trap destination 1
SNMP TRAP2 : SNMP trap destination 2
GMT (+) :
Time lag from the Greenwich mean time (Unit: hour).
Contact :
Administrator information of the device
Name :
Administrator information of the device
Location :
Information of the location where the device is installed.
UNIQUE No :
Used for controlling inside the device (normally not used).
m
. When connecting the upper level controller (*1) via Ethernet, "OPT1 PORT=" and "OPT2 PORT="
should be set to the same values respectively as those of the upper level controller.
. When connecting multiple IXS series units via Ethernet, "OPT3 PORT=" should be set to the same
value in each unit.
(*1) BZR-IF830, BZR-240 etc.