D1103 (A-5): REM1 B TX
REMOTE1 connector S-BUS data send status indication
Lights for a period of 0.015 seconds when the system sends
data to the data link through the REMOTE1 B1 or B2
connector.
D1104 (A-5): REM1 C TX
REMOTE1 connector S-BUS data send status indication
Lights for a period of 0.015 seconds when the system
sends data to the data link through the REMOTE1 C
connector.
D1201 (A-5): PRIM-A
S-BUS status indication
Lights when the S-BUS A system is assigned to the
primary station.
D1202 (A-5): PRIM-B/C
S-BUS status indication
Lights when the S-BUS B/C systems are assigned to the
primary stations.
D1203 (A-5): SYNC
REMOTE1 communication status indication
Lights when the REMOTE1 communication is in the
communication mode in which the communication is
performed in synchronism with reference.
D1301 to D1314 (C-5)
Used only for production in the assembly factory. All
LEDs light or flash for normal operation.
D1315 (A-5): REM2 A TX
REMOTE2 connector data send status indication
Lights for a period of 0.015 seconds when the system sends
data to the data line through the REMOTE2 A connector.
D1316 (A-5): REM2 A RX
REMOTE2 connector data reception status indication
Lights for a period of 0.015 seconds when the system receives
data from the data line through the REMOTE2 A connector.
D1317 (A-5): REM2 B TX
REMOTE2 connector data send status indication
Lights for a period of 0.015 seconds when the system sends
data to the data line through the REMOTE2 B connector.
D1318 (A-5): REM2 B RX
REMOTE2 connector data reception status indication
Lights for a period of 0.015 seconds when the system re-
ceives data from the data line through the REMOTE2 B con-
nector.
D1319 (J-5)
Used only for production in the assembly factory. It lights
or flashes for normal operation.
IXS-6600/6700
D1320 (J-5)
Used only for production in the assembly factory. It turns
off for normal operation.
D1504, D1503, D1502, D1501 (J-6):
Used only for production in the assembly factory. All
LEDs light or flash for normal operation.
D2201 (R-1): + + + + + 12 V-CTRL
+12 V-CTRL power supply status indication
Lights when the +12 V-CTRL power is supplied normally.
D2203 (F-5)
Used only for production in the assembly factory. It turns
off for normal operation.
D2207 (E-5)
Used only for production in the assembly factory. It turns
off for normal operation.
D2208 (P-1): + + + + + 12 V
+12 V power supply status indication
Lights when the +12 V power is supplied normally.
D2214 (P-1): 3.3 V
+3.3 V power supply status indication
Lights when the +3.3 V power is supplied normally.
D2215 (J-1): 5 V
+5 V power supply status indication
Lights when the +5 V power is supplied normally.
D2216 (G-6): 1.5 V
+1.5 V power supply status indication
Lights when the +1.5 V power is supplied normally.
D2217 (R-1): + + + + + 12 V_MAIN
+12 V_MAIN power supply status indication
Lights when the +12 V_MAIN power is supplied normal-
ly.
If this LED does not light, the fuse may have blown.
D2401 (G-4): ROM SWAP
Indicates the startup status of software from flash ROM in
which program is stored.
This LED turns off for normal operation.
<Switch >
S1 (A-5): RESET
The reset switch that is used to reset operations of the CA-
65 printed circuit board.
S101 (C-5): MON
This is the test switch that should be used only for produc-
tion in the assembly factory.