Water Pump Maintenance - Trane CONQUEST CGAX 015 Installation Operation & Maintenance

Air-cooled scroll chillers and heat pumps 43-164 kw
Table of Contents

Advertisement

Maintenance

Water pump maintenance

WARNING! Before starting work on the pump, make sure
that the power supply has been switched off and that it
cannot be accidentally switched on. The internal pump
FWD
parts are maintenance-free. It is important to keep the
Power supply
motor clean in order to ensure adequate cooling of the
Capacities
Cooling capacity on water (1)
motor. If the pump is installed in dusty environments,
Heating capacity on water (2)
it must be cleaned and checked regularly. Take the
Fan motor
enclosure class of the motor into account when cleaning.
Fan power input (3)
The motor has maintenance-free, greased-for-life
Current amps (3)
Start-up amps
bearings.
Air flow
If the water loop must be emptied during period of frost,
minimum
nominal
the pump has to be drained to avoid damage.
maximum
Remove the filling and drain plugs.
Main coil
Water entering/leaving connections
Do not refit the plugs until the pump is taken into
operation again.
Electric heater (accessory for blower only)
Electric power supply
Figure 15 - Water pump plug locations
Heating capacity
Hot water coil (accessory for blower only)
Heating capacity (4)
G2 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
Water flow - lift height
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
Sound power level (5)
Unit dimensions
Width x Depth
Height
Shipped unit dimensions
Width x Depth
Height
Weight
Colour
Recommended fuse size
A = Filling plug
Unit alone (aM/gI)
B = Drain plug
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
4
50
Technical Data
08
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CG-SVX027D-GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents