Maintenance
7.3 Corrective Maintenance
Installing the active parts of the bearings
NOTICE
Before mounting the bearings, ensure that the parts and components that are to be located
on the shaft inside the bearing have been mounted beforehand!
To fit the bearings on the shaft, heat them up to about 80°C in oil or air.
Then push the bearings onto the shaft up to its shoulder.
NOTICE
Avoid any heavy blows that might damage the bearings.
Fill the bearings with specified grease (see section entitled "Types of grease") until it is flush.
Also observe the following installation condition:
● If rotary shaft seals without helical springs are installed, the replacement part must also
[ID: 378.01]
7.3.4

Screw-type connections

Tightening torque for screwed union connections
The screwed union connections with metal contact surfaces (end shields, active bearing
parts, terminal box parts bolted onto the stator frame) should be tightened to the following
torque with a tolerance of ± 10 %, depending on the thread size.
Table 7-3
Thread size
Tightening torque [Nm]
Please refer to the relevant sections and drawings for all other tightening torques (electrical
connections and bolted connections for parts with flat gaskets).
Bolt locking devices
Nuts or bolts that are mounted together with locking, resilient and/or force-distributing
elements (e.g., safety plates, spring-lock washers, etc.) must be refitted together with
identical, fully functional elements.
Always replace keyed elements.
[ID: 379.01]
62
be installed without a spring.
Tightening torque for screwed union connections
M6
M8
M10
8
20
40
M12
M16
70
170
Siemens AG Operating Instructions 2.02 1PL618
M20
M24
340
600
A5E00215731A AD